Sold Industrial Property (NC003547)

Address:
205 Industrial Park Access Rd.
Polk County
Columbus, NC 28722
Building Size:
47,269 SF
Lot Size:
8 Acres
Expansion ground w/pre-graded expansion pad to allow for a doubling of the production space on site.
Property Description
Year Built
1998 / 0
Quality
Excellent
Office
5,120 SF
Dimensions : 32' X 160'
Dimensions
223'2" X 160'/32' X 160'/149'8" X 25'
Ceiling Height
Min: 25' 6", Max: 27' 2"
Ceiling Type
Metal - Insulated
Ceiling Comments
Exposed vinyl backed insulation, beams and joists27' 2" clear below the beams at center25' 6" clear below beams at eaves
Column Spacing
25' x 80'
Column Comments
25' x 80' (offset end wall spacings of 24'6" and 25'10"
Column Type
Steel H
Roof
Standing Seam Metal - Insulated standing seam metal roof system with center ridge ventDesign Loads: Dead load 3 PSF Collateral 10 PSF Roof live 20 PSF Roof snow 20 PSF Wind velocity 90 MPH
Floors
Reinforced Concrete - Floor: North Side of Plant: 6" concrete floor slabs reinforced with wire welded mesh with some areas having up to 10" concrete floor slabs reinforced with either wire welded mesh or rebar. South Side of Plant: 6" concrete floor slabs reinforced with wire welded mesh
Walls
Metal -- corrugated steel - 26 gauge corrugated metal panels with 3.5" of exposed vinyl backed insulation, protected by a corrugated metal interior liner panel to a height of 7'4"
Lighting
T-8 light fixtures throughout production areaExterior roof and gutters
Loading
2 - 9 'x 10' dock high loading door3 - 14 'x 20' ground level drive-in door
Cranes
South Bay - 1 - 10 ton overhead bridge crane with 74' span, 220' travel and 22' under hook height (2 - 5 ton hoists)North Bay - Structural steel capacity to accommodate up to one additional 10-ton overhead bridge crane
Parking
38 paved , marked and lighted spaces with additional overnight trailer storage in the fenced paved area
Rail
No
Gas
Public Service Company
Water
City
Sewer
City
Power
Duke Power Company
44 kV transmission system12.47 Kv primary distribution line at substation7500 kVA interior pad mounted transformer480y/277V, 3 phase 4 wire
Heat
Gas
Ceiling mounted gas fired unit heaters over the ground level drive-in doors
Air Conditioning
No - Office only
Sprinklers
No
Ventilation
Roof mounted center ridge vent
Air Line
1 - 100 HP Sullivan screw type air compressor 1 - 750 SCFM Ingersol Rand air drier 1 - Receiving tank All air distribution lines in the plant remain in place
Last Use
Steel ring processing facility

Map
  View Large Map  -  Directions To  -  Directions From
Extended Market Coverage Group - 2907 Providence Road, Suite 302 - Charlotte, NC 28211 - 704.208.5243 - tturner@ngkf.com
All information furnished is from sources deemed reliable, but no warranty or representation is made as to the accuracy thereof and same is submitted subject to errors, omissions, change of price, rental or other conditions, prior sale, lease or financing, or withdrawal without notice. No liability of any kind is to be imposed on the broker herein.

Bookmark and Share