Available Industrial Property (NC002496)
Address:
1000 Candle Wycke Ln.
Surry County
Elkin, NC 28621
Location:
65 miles north of Charlotte, I-77
Building Size:
416,007 SF
Lot Size:
37.40 Acres + 12.60 Acres
Attachments
Brochure
Download
Property Description
Year Built
1997
Quality
Excellent
Office
15,327 SF
15,327 sf of offices featuring a lobby & reception area, 5 private offices, 2 conference rooms a training room, a large general clerical area accommodating moveable partitions, vending area, gift shop, computer & telephone switch room, canteen & breakroom, men’s & women’s office restrooms & plt restrooms & locker rooms for both male & female employees.
Finishes include dropped acoustical ceiling tiles, painted gypsum wall panels, carpeted & tiled floors & recessed fluorescent light fixtures
Dimensions
712 x 551
Ceiling Height
Min: 25' 9", Max: 32' 5"
Ceiling Comments
Exposed vinyl backed insulation and exposed beams and joists.
Column Spacing
71' x 55'
Column Comments
10" steel H
Predominately 71’4” x 55’5”
Length: 71’4” with an offset along the east wall of 70’
Width: 55’5” with an offset along the north wall of 43’8” and an offset along the south wall of 49’8”. The spacing between the 7th and 8th column lines is 70’
Column Type
Steel H
Roof
Office – EPDM over rigid insulation mechanically fastened to a 22 gage metal deck.
Warehouse – Standing Seam metal roof panels with exposed vinyl backed insulation. The roof was recoated in 2007 with a 10-year guarantee.
Floors
Slab A–Office–4” concrete fl over vapor barrier & 4” crushed stone
Slab B–Isles, Mezzanine & Truck Staging–6 1/2" (4000 psi) concrete fl reinforced w/steel fibers & wet cured over vapor barrier & 4” crushed stone w/slab tolerance of FF–35 & FL25
Slab C–Racking–7 1/2” (4000 psi) concrete fl reinforced w/steel fibers & wet cured over vapor barrier & 4” crushed stone w/slab tolerance of FF–50 & FL30
*Slab detail plan available
(See additional info under special features)
Walls
Split faced block wainscot to a height of 8' and 10' with the balance being insulated pre-engineered metal panels.
Lighting
400 watt Day Bright metal halide fixtures for racked areas and double tube fluorescent track fixtures for the mezzanine areas
Loading
East Wall: 25 – 8’ 8” x 10’ dock height insulated loading doors with Right Height hydraulic load levelers, dock lights, dock seals, bumper pads and dock locks
North Wall: 1 – 12’ x 12’ manual roll up drive-in door
South Wall: 1 – 12’’ x 12’ manual roll up drive-in door
Parking
432 paved, marked and lighted spaces.
Rail
No
Gas
Frontier Natural Gas - Supplied by Frontier Natural Gas
4” main with 55 psi 800 feet away from property. Extension possible.
Currently supplied by 18,000 gallon onsite liquid propane storage tank
*Available .5 miles at the end of Candle Wycke on NC 268
Water
City
Sewer
City
Power
Duke Energy Company
Primary: 12 kv
Transformers: 1 – 2,000 KVA pad mounted transformer
Switchgear: 1 – 3000 amp Square D – 480 / 277y – 3 phase, 4 wire
Distribution: Direct Feed
Heat
Gas
Shipping Office – 2 – Trane – 5 ton ground mounted heat pump units.
Warehouse – Heat - 4 gas fired Powermatic air rotation units.
Office – 2 – Trane – 20 ton roof mounted gas pack units
Air Conditioning
Yes - Warehouse - AC- 4 Trane - 105 ton ground mounted units ducted into the east and west side walls.
Office – 2 – Trane – 20 ton roof mounted gas pack units
Sprinklers
Yes - Overhead wet sprinkler system (ESFR) with a design criteria for 242,500 sq ft of 28’6” high open rack storage. The sprinkler system is supplied by a 160,000 gallon onsite ground level water storage tank. An electric jockey pump maintains pressure of 150 psi. A diesel fire pump (300 gallon above ground storage tank) supplies fire protection water at 2,000 gpm and 145 psi to a 10” fire loop and 10 – 8” risers from the water tank.
Ventilation
4 louvered centrifugal exhaust fans located on the west wall.
Air Line
1 Ingersoll Rand Compressor and Dryer at 40 hp with 163 cfm and 125 psig
1 Ingersoll Rand Compressor at 50 hp with 165 psi output
Special Features
Slab D–Mechanical & Support–6 1/2" (4000 psi) concrete fl reinforced w/steel fibers & wet cured over vapor barrier & 4” crushed stone w/slab tolerance of FF–35 & FL25
Slab E–70’ Bay & Fl under Nonstructural Mezzanine–8” (4000 psi) concrete fl reinforced w/steel fibers & wet cured over vapor barrier & 4” crushed stone w/slab tolerance of FF–35 & FL25
Mezzanine–3” light wt. concrete reinforced w/6x6 wwf over 28 gauge galvanized metal decking w/38 lbs/sf dead load & 100 lbs/sf live load
Miscellaneous
Warehouse: 395,798 sf (712' x 551)
Office: 15,327 sf (258’4” x 59’4")
Bale Storage: 2,400 sf (75' x 32’)
Support Area: 2,482 sf (25'4" x 55'4" & 25'4" x 42'8")
Structural Mezzanine: 44,800 sf which is not included in the overall footprint.
Data control system, 8,780 linear feet of power conveyor, RF system, sortation system and 44,800 sf of mezzanine not included in the total square footage.
Surry County is a Tier 1 county for JDIG Grants.
Last Use
Distribution of candles
Hart Corporation
-
900 Jaymor Rd, Southampton, PA 18966
-
1-800-368-4278
-
hart@hartcorp.com
All information furnished is from sources deemed reliable, but no warranty or representation is made as to the accuracy thereof and same is submitted subject to errors, omissions, change of price, rental or other conditions, without notice. No liability of any kind is to be imposed on the broker herein.